  • Many error messages are also shown on the on-board computer
     
  • Example: Show error code 0x410015 in the display as 410

 

Fast Charger (BCS250)

error code
DiagnosticTool /
Display

Precise description of fault

Remedy

0xB0B010
0xB0B030
Fast Charger voltage error Disconnect the Fast Charger from mains voltage for at
least 30 seconds then plug it in again
0xB0B031 Voltage difference between battery
and Fast Charger is too great
Disconnect the Fast Charger from mains voltage for at least
30 seconds then plug it in again. If the problem persists,
cross-swap the battery, battery cable or battery charging
socket
0xB0B110
0xB0B120
0xB0B125
0xB0B130
Error on the charging socket Disconnect the Fast Charger from mains voltage for at
least 30 seconds then plug it in again. If the problem
persists, check the charging socket for dirt and, if
necessary, cross-swap with the rechargeable battery
0xB22100 Fast Charger temperature too high Disconnect the Fast Charger from mains voltage and wait at
least 30 minutes
0xB22200 Fast Charger temperature too low Disconnect the Fast Charger from mains voltage and wait at
least 30 minutes
0xB22300
0xB22400
Hardware error Disconnect the Fast Charger from mains voltage for at
least 30 seconds then plug it in again
0xB41000
0xB42000
Battery voltage error Disconnect the Fast Charger from mains voltage for at
least 30 seconds then plug it in again. If the problem
persists, carry out a battery cross-swap
0xB43000
0xB45000
0xB46000
Fast Charger voltage error Disconnect the Fast Charger from mains voltage for at
least 30 seconds then plug it in again. If the problem
persists, carry out a battery cross-swap
0xB51000 Current difference between battery
and Fast Charger is too great
Disconnect the Fast Charger from mains voltage for at
least 30 seconds then plug it in again. If the problem
persists, carry out a battery cross-swap
0xB52000 Current measurement has failed Disconnect the Fast Charger from mains voltage for at
least 30 seconds then plug it in again
0xB58000
0xB59000
Error curing current regulation Disconnect the Fast Charger from mains voltage for at
least 30 seconds then plug it in again
0xB7177A Second charger detected Make sure only one charger is connected to the bicycle
0xBA1001
0xBA1004
0xBA5001
0xBC0101
0xBC0102
0xBC0103
0xBC0104
0xBC0105
0xBC0106
0xBC0107
0xBC0110
0xBC0111
0xBC0112
0xBC0113
0xBC0120
0xBC0121
0xBC0122
0xBC0123
0xBC0124
Internal software error Disconnect the Fast Charger from mains voltage for at
least 30 seconds then plug it in again
0xBA1005
0xBA1040
Calibration error Disconnect the Fast Charger from mains voltage for at
least 30 seconds then plug it in again
0xBB0000 Incorrect software version Check the software version of the Fast Charger.
Disconnect the Fast Charger from mains voltage for at
least 30 seconds then plug it in again
0xBC0130
0xBC0131
0xBC0132
Internal software error Disconnect the Fast Charger from mains voltage for at
least 30 seconds then plug it in again
0xBE1001 Internal software error Check the software version of the Fast Charger.
Disconnect the Fast Charger from mains voltage for at
least 30 seconds then plug it in again
0xBE1002
0xBE1003
Incorrect hardware version Check the software version of the Fast Charger.
Disconnect the Fast Charger from mains voltage for at
least 30 seconds then plug it in again
0xBE1010
0xBE1020
0xBE1030
0xBE1040
Hardware self-test failed Disconnect the Fast Charger from mains voltage for at
least 30 seconds then plug it in again

 

 

-

 

 

PowerPack 300 (BBS / BBR 240 / 245) / 400 (BBS / BBR 260 / 265) / 500 (BBS / BBR 270 / 275),
PowerTube 400 (BBP282 / 283) / 500 (BBP280 / 281) / 625 (BBP290 / 291)

error code
DiagnosticTool /
Display

Precise description of fault

Remedy

0x602040 Internal battery error → No voltage
supply, system shutdown
 
0x602041 Internal charging error → System
shutdown
Disconnect charger,
restart system
0x60303C Discharging error. Excessive current
during discharging → No voltage
supply, system shutdown
 
0x605007 Temperature error. Insufficient
temperature during charging → No
voltage supply, system shutdown
Allow the battery to warm slowly to room temperature
0x605008 Temperature error. Excessive
temperature found during charging
→ Charging is discontinued
Stop charging. Allow the battery to cool slowly to room
temperature
0x60502A Temperature error. Excessive
temperature during discharging →
No voltage supply, system
shutdown
Allow the battery to cool slowly to room temperature
0x60502B Temperature error. Insufficient
temperature during discharging →
No voltage supply, system
shutdown
Allow the battery to warm slowly to room temperature
0x606011 External short circuit → No voltage
supply, system shutdown
Check plug and cable for damage or tampering
0x61000E Voltage error. Insufficient cell
voltage → No voltage supply,
system shutdown
 
0x61000F Voltage error. Surge cell voltage →
Shutdown charging
 
0x620001 Charger error Replace the charger. Run the software update
0x620002 Multiple system charges detected
at the same time
Please connect only one charger to the system. Run the
software update
0x631005 Software error Replace battery
0x64004B Voltage limit exceeded → No
voltage supply, system shutdown
 
0x655001
0x655002
0x655003
0x655004
0x655005
0x657002
Multiple battery error → No voltage
supply, system shutdown
Switch off the eBike, remove and reinstall the batteries,
restart the system
0x655009 Multi-battery error  
0x656001 Configuration error → No voltage
supply, system shutdown
Software update
0x656003 Software version error. Invalid
software version → No voltage
supply, system shutdown
Software update
0x656005 Configuration error Run the software update
0x658001 More than one battery was
detected on the eBike system
Remove a battery from the eBike system.
0x660001 Battery deactivated Battery is permanently deactivated and ready for disposal.
Print the diagnostic report. If you have any questions call
the Bosch eBike Service Team
0x677001 Battery is a sample Call the Bosch eBike Service Team
0x678001 Internal battery error; the battery is
missing necessary parameters
 
0x680001 Hold down the battery's [On / Off]
button
Check the [On / Off] button for damage a tendency to stick.
When the battery is removed, the charge level indicator should
go out after a maximum of 10 seconds
0x6A0001 Internal software error  
0x6A0003
0x6A0006
0x6A0009
Temperature error. Implausible
temperature found → No voltage
supply, system shutdown
 
0x6A0004
0x6A000A
Temperature error. Insufficient
temperature
Allow the battery to warm slowly to room temperature
0x6A0005
0x6A000B
Temperature error. Excessive
temperature → No voltage supply,
system shutdown
Allow the battery to cool slowly to room temperature
0x6A0010 Internal communication error → No
voltage supply, system shutdown
 
0x6A0011
0x6A0051
0x6A0052
Internal error  
0x6A0012
0x6A0028
Internal battery error → No voltage
supply, system shutdown
 
0x6A001E [On / Off] button error → No
voltage supply, system shutdown
Check the battery's [On / Off] button for defects
0x6A002C
0x6A002D
Voltage error → No voltage supply,
system shutdown
 
0x6A0032 Internal battery cell error → No
voltage supply, system shutdown
 
0x6A0033 Charger error → Discontinue
charging
Replace the charger
0x6A0039 Current direction errors. Battery is
charged in discharge mode → No
voltage supply, system shutdown
Check for original Bosch eBike system components
0x6A003A
0x6A003D
Current error → No voltage supply,
system shutdown
 
0x6A003B Current direction errors. Battery
has been discharged in charging
mode → No voltage supply, system
shutdown
Check for original Bosch eBike system components.
Replace the charger
0x6A003C Discharging error. Excessive current
during discharge process
Check for original Bosch eBike system components.
Remove the batteries, press and hold the [On / Off] button
for 10 seconds, re-connect, restart the system
0x6A003E
0x6A0049
0x6A004A
Internal battery error → No voltage
supply, system shutdown
 
0x6A003F Internal hardware error  
0x6A0041
0x6A0044
Voltage error. Implausible battery
voltage → No voltage supply,
system shutdown
Disconnect charger and restart charging cycle
0x6A0042
0x6A0045
Voltage error. Overvoltage Disconnect charger and restart charging cycle
0x6A0046 Voltage error. Undervoltage Disconnect charger and restart charging cycle
0x6A004C Charging error. Excessive current
during charging → No voltage
supply, system shutdown
 
0x6A004D Internal signal error → Charging
process is switched off
 
0x6A0050 Multiple battery error → No voltage
supply, system shutdown
Turn off eBike, remove batteries, reconnect, reboot the
system
0x6A0051
0x6A0052
Internal error  
0x6A1001
0x6A1004
Internal software error  
0x6A1005 Internal hardware error Replace battery
0x6A1006 Internal software error Remove the batteries, press and hold the “on / off” switch
for 10 seconds, re-connect, restart the system

 

 

 

 

-

 

 