Overview of error codes
Error code indicator on the on-board computer
-
Many error messages are also shown on the on-board computer
- Example: Show error code 0x410015 in the display as 410
Fast Charger (BCS250)
error code
|
Precise description of fault |
Remedy |
---|---|---|
0xB0B010 0xB0B030 |
Fast Charger voltage error |
Disconnect the Fast Charger from mains voltage for at least 30 seconds then plug it in again |
0xB0B031 |
Voltage difference between battery and Fast Charger is too great |
Disconnect the Fast Charger from mains voltage for at least 30 seconds then plug it in again. If the problem persists, cross-swap the battery, battery cable or battery charging socket |
0xB0B110 0xB0B120 0xB0B125 0xB0B130 |
Error on the charging socket |
Disconnect the Fast Charger from mains voltage for at least 30 seconds then plug it in again. If the problem persists, check the charging socket for dirt and, if necessary, cross-swap with the rechargeable battery |
0xB22100 | Fast Charger temperature too high |
Disconnect the Fast Charger from mains voltage and wait at least 30 minutes |
0xB22200 | Fast Charger temperature too low |
Disconnect the Fast Charger from mains voltage and wait at least 30 minutes |
0xB22300 0xB22400 |
Hardware error |
Disconnect the Fast Charger from mains voltage for at least 30 seconds then plug it in again |
0xB41000 0xB42000 |
Battery voltage error |
Disconnect the Fast Charger from mains voltage for at least 30 seconds then plug it in again. If the problem persists, carry out a battery cross-swap |
0xB43000 0xB45000 0xB46000 |
Fast Charger voltage error |
Disconnect the Fast Charger from mains voltage for at least 30 seconds then plug it in again. If the problem persists, carry out a battery cross-swap |
0xB51000 |
Current difference between battery and Fast Charger is too great |
Disconnect the Fast Charger from mains voltage for at least 30 seconds then plug it in again. If the problem persists, carry out a battery cross-swap |
0xB52000 | Current measurement has failed |
Disconnect the Fast Charger from mains voltage for at least 30 seconds then plug it in again |
0xB58000 0xB59000 |
Error curing current regulation |
Disconnect the Fast Charger from mains voltage for at least 30 seconds then plug it in again |
0xB7177A | Second charger detected | Make sure only one charger is connected to the bicycle |
0xBA1001 0xBA1004 0xBA5001 0xBC0101 0xBC0102 0xBC0103 0xBC0104 0xBC0105 0xBC0106 0xBC0107 0xBC0110 0xBC0111 0xBC0112 0xBC0113 0xBC0120 0xBC0121 0xBC0122 0xBC0123 0xBC0124 |
Internal software error |
Disconnect the Fast Charger from mains voltage for at least 30 seconds then plug it in again |
0xBA1005 0xBA1040 |
Calibration error |
Disconnect the Fast Charger from mains voltage for at least 30 seconds then plug it in again |
0xBB0000 | Incorrect software version |
Check the software version of the Fast Charger. Disconnect the Fast Charger from mains voltage for at least 30 seconds then plug it in again |
0xBC0130 0xBC0131 0xBC0132 |
Internal software error |
Disconnect the Fast Charger from mains voltage for at least 30 seconds then plug it in again |
0xBE1001 | Internal software error |
Check the software version of the Fast Charger. Disconnect the Fast Charger from mains voltage for at least 30 seconds then plug it in again |
0xBE1002 0xBE1003 |
Incorrect hardware version |
Check the software version of the Fast Charger. Disconnect the Fast Charger from mains voltage for at least 30 seconds then plug it in again |
0xBE1010 0xBE1020 0xBE1030 0xBE1040 |
Hardware self-test failed |
Disconnect the Fast Charger from mains voltage for at least 30 seconds then plug it in again |
-
PowerPack 300 (BBS / BBR 240 / 245) / 400 (BBS / BBR 260 / 265) / 500 (BBS / BBR 270 / 275),
PowerTube 400 (BBP282 / 283) / 500 (BBP280 / 281) / 625 (BBP290 / 291)
error code
|
Precise description of fault |
Remedy |
---|---|---|
0x602040 |
Internal battery error → No voltage supply, system shutdown |
|
0x602041 |
Internal charging error → System shutdown |
Disconnect charger, restart system |
0x60303C |
Discharging error. Excessive current during discharging → No voltage supply, system shutdown |
|
0x605007 |
Temperature error. Insufficient temperature during charging → No voltage supply, system shutdown |
Allow the battery to warm slowly to room temperature |
0x605008 |
Temperature error. Excessive temperature found during charging → Charging is discontinued |
Stop charging. Allow the battery to cool slowly to room temperature |
0x60502A |
Temperature error. Excessive temperature during discharging → No voltage supply, system shutdown |
Allow the battery to cool slowly to room temperature |
0x60502B |
Temperature error. Insufficient temperature during discharging → No voltage supply, system shutdown |
Allow the battery to warm slowly to room temperature |
0x606011 |
External short circuit → No voltage supply, system shutdown |
Check plug and cable for damage or tampering |
0x61000E |
Voltage error. Insufficient cell voltage → No voltage supply, system shutdown |
|
0x61000F |
Voltage error. Surge cell voltage → Shutdown charging |
|
0x620001 | Charger error | Replace the charger. Run the software update |
0x620002 |
Multiple system charges detected at the same time |
Please connect only one charger to the system. Run the software update |
0x631005 | Software error | Replace battery |
0x64004B |
Voltage limit exceeded → No voltage supply, system shutdown |
|
0x655001 0x655002 0x655003 0x655004 0x655005 0x657002 |
Multiple battery error → No voltage supply, system shutdown |
Switch off the eBike, remove and reinstall the batteries, restart the system |
0x655009 | Multi-battery error | |
0x656001 |
Configuration error → No voltage supply, system shutdown |
Software update |
0x656003 |
Software version error. Invalid software version → No voltage supply, system shutdown |
Software update |
0x656005 | Configuration error | Run the software update |
0x658001 |
More than one battery was detected on the eBike system |
Remove a battery from the eBike system. |
0x660001 | Battery deactivated |
Battery is permanently deactivated and ready for disposal. Print the diagnostic report. If you have any questions call the Bosch eBike Service Team |
0x677001 | Battery is a sample | Call the Bosch eBike Service Team |
0x678001 |
Internal battery error; the battery is missing necessary parameters |
|
0x680001 |
Hold down the battery's [On / Off] button |
Check the [On / Off] button for damage a tendency to stick. When the battery is removed, the charge level indicator should go out after a maximum of 10 seconds |
0x6A0001 | Internal software error | |
0x6A0003 0x6A0006 0x6A0009 |
Temperature error. Implausible temperature found → No voltage supply, system shutdown |
|
0x6A0004 0x6A000A |
Temperature error. Insufficient temperature |
Allow the battery to warm slowly to room temperature |
0x6A0005 0x6A000B |
Temperature error. Excessive temperature → No voltage supply, system shutdown |
Allow the battery to cool slowly to room temperature |
0x6A0010 |
Internal communication error → No voltage supply, system shutdown |
|
0x6A0011 0x6A0051 0x6A0052 |
Internal error | |
0x6A0012 0x6A0028 |
Internal battery error → No voltage supply, system shutdown |
|
0x6A001E |
[On / Off] button error → No voltage supply, system shutdown |
Check the battery's [On / Off] button for defects |
0x6A002C 0x6A002D |
Voltage error → No voltage supply, system shutdown |
|
0x6A0032 |
Internal battery cell error → No voltage supply, system shutdown |
|
0x6A0033 |
Charger error → Discontinue charging |
Replace the charger |
0x6A0039 |
Current direction errors. Battery is charged in discharge mode → No voltage supply, system shutdown |
Check for original Bosch eBike system components |
0x6A003A 0x6A003D |
Current error → No voltage supply, system shutdown |
|
0x6A003B |
Current direction errors. Battery has been discharged in charging mode → No voltage supply, system shutdown |
Check for original Bosch eBike system components. Replace the charger |
0x6A003C |
Discharging error. Excessive current during discharge process |
Check for original Bosch eBike system components. Remove the batteries, press and hold the [On / Off] button for 10 seconds, re-connect, restart the system |
0x6A003E 0x6A0049 0x6A004A |
Internal battery error → No voltage supply, system shutdown |
|
0x6A003F | Internal hardware error | |
0x6A0041 0x6A0044 |
Voltage error. Implausible battery voltage → No voltage supply, system shutdown |
Disconnect charger and restart charging cycle |
0x6A0042 0x6A0045 |
Voltage error. Overvoltage | Disconnect charger and restart charging cycle |
0x6A0046 | Voltage error. Undervoltage | Disconnect charger and restart charging cycle |
0x6A004C |
Charging error. Excessive current during charging → No voltage supply, system shutdown |
|
0x6A004D |
Internal signal error → Charging process is switched off |
|
0x6A0050 |
Multiple battery error → No voltage supply, system shutdown |
Turn off eBike, remove batteries, reconnect, reboot the system |
0x6A0051 0x6A0052 |
Internal error | |
0x6A1001 0x6A1004 |
Internal software error | |
0x6A1005 | Internal hardware error | Replace battery |
0x6A1006 | Internal software error |
Remove the batteries, press and hold the “on / off” switch for 10 seconds, re-connect, restart the system |
-